Page 14 - MERC Flip Template

Basic HTML Version

MERC – Membrane Filter Test Plan
12
Appendix 1: Vendor Proposed Test Format
Proposed Tests
A list of the six planned tests is provided below:
General Test Parameters
10 gpm constant filtered water flow
Test length – 5 hrs or until the pressure drop across the 0.1 um filter reaches 30 psid
Total test volume – 3000 gallons or total volume filtered before reaching 30 psid pressure drop (0.1um filter)
Test #1 – Filter #1, 20”, 0.1um
Test #2 – Filter #5, 20”, 0.1 um
Test #3 – Filter #2, 20”, 20um
Filter #1, 20”, 0.1 um
Test #4 – Filter #2, 20”, 20um
Filter #5, 20”, 0.1 um
Test #5 – Filter #2, 20”, 20um
Filter #3, 20”, 10 um
Filter #4, 20”, 5um Filter #1, 20”, 0.1 um
Test #6 - Filter #2, 20”, 20um
Filter #3, 20”, 10 um
Filter #4, 20”, 5um Filter #5, 20”, 0.1 um
Calinration Run – January 5
th
A dry run of the anticipated testing will be performed on January 5
th
. During the dry run, we plan
to do the following:
1. Complete the installation of the test skid, sample piping, and low-level TSS set-up.
a. Change out three DP meters from the current 0-15 psid gauges to 0-30 psid gauges
b. Connect tubing from the final three sample ports to the overflow buckets
c. Connect tubing from the overflow buckets to the TSS sample filter pumps, 0.45um
filter, and measurement jugs.
Vent
Filter
Housing
Vent
Filter
Housing
F
DP Meter
DP Meter
20"Filter
Vent
Filter
Housing
DP Meter
Vent
DP Meter
Drain
Drain
Drain
Pressure
Gauge
Pressure
Gauge
Flow Meter
Sample Valve
3/8" Ball Valve
20"Filter
Housing
20"Filter
Housing
20"Filter
Housing
1"
1"to 3/4"
1" Ball Valve
1/4" Ball valve
Sample Valve
3/8" Ball Valve
Sample Valve
3/8" Ball Valve
Sample Valve
3/8" Ball Valve
Drain
To Drain or MERC
Sample container
To Drain or MERC
Sample container
Drain
3/8" Tygon Tubing
3/8" Tygon Tubing
3/8" Tygon Tubing
Measurement container
0.45 filter
Sample pump
Measurement container
0.45 filter
Sample pump
Measurement container
0.45 filter
Sample pump
#1
#2
#3
#4