Page 26 - MERC Flip Template

Basic HTML Version

MERC STDN Test Plan
24
Table 7. Summary of Test Conditions and Test Acceptability Criteria for the Mysid
Americamysis bahia
Larval Survival and Growth Chronic Test
Test type:
Static renewal
Test Duration:
7 d
Temperature:
26ºC (± 1ºC)
Lighting:
Normal laboratory fluorescent
Photoperiod:
16 h light, 8 h dark
Test chamber size:
400 ml
Test solution volume:
150 ml
Renewal of test solutions:
Daily
Age of test organisms:
7 d
No. organisms per test chamber:
5
No. replicate chambers per concentration:
8
No. organisms per test concentration:
40
Feeding regime:
Feed 150 <24 h old
Artemia
nauplii daily, half
after test solution renewal and half after 8-12 h.
Cleaning:
Siphon daily immediately before test solution
renewal and feeding.
Aeration:
None, unless DO concentration falls below 4.0
mg/l. Rate should not exceed 100 bubbles/min
Dilution water:
Baltimore Harbor water collected at the same
time as the initial untreated ballast water
Test concentrations:
100, 56, 32, 18, and 10 % ballast discharge or
receiving water by volume plus a Baltimore
Harbor and a Wye River control
Dilution factor:
0.56 dilution series
Endpoint:
Survival and growth (dry weight)
Test acceptability criteria:
80% or greater survival in controls; average
dry weight per surviving organism in control
chamber equals or exceeds 0.20 mg; fecundity
may be used if 50% or more of females in
controls produce eggs.