Page 5 - MERC Flip Template

Basic HTML Version

MERC+GSI – DRAFT Test Plan
3
Table 1. Ranges of various physical and biological parameters in ambient water during the testing season
(March/April – October/November) in the Port of Baltimore in comparison to ETV/USCG and IMO G8
recommended challenge conditions. Port of Baltimore data collected by MERC and various academic
and agency studies or monitoring efforts in the general location of the
Cape Washington
(Patapsco River).
Ranges in various physical and biological parameters of ambient water during the testing season (July –
September) in the Duluth/Superior Harbor collected by GSI.
Generic Protocol for the Verification of Ballast Water Treatment Technologies: Draft v4 2008, US EPA
Environmental Technology Verification (ETV) program under contract to US Coast Guard.
IMO Guidelines for the Approval of Ballast Water Management Systems (G8), October 2008, Annex 4
Resolution MEPC.174(58).
* TSS, POC and DOC (2004-2007) MD DNR Chesapeake Bay Water Quality database:
www.chesapeakebay.net/data_waterquality.aspx. Zooplankton (1998 – 2002) and phytoplankton (2004-
2007) Chesapeake Bay Program: www.chesapeakebay.net/data_plankton.aspx. Bacteria (1998 – present)
Cowell and Huq, University of Maryland; Louis et al. 2003, AEM 69:2773-2785.
Values collected by GSI in 2007 and 2008 as part of facility validations and treatment systems testing
www.nemw.org/GSI/.
For this specific evaluation of the SiCURE treatment system, Siemens Water
Technologies has made a special request to MERC and GSI to augment intake water to more
consistently approach the initial challenge water conditions described in the G8 guidelines during
the test trials. While MERC and GSI do not make any guarantees on the precise conditions of
challenge water, humic acid and Arizona Test Dust (as proposed by ETV and NRL Key West)
will be injected inline during initial filling of control and test tanks at MERC and GSI to increase
TSS, POC and DOC levels, and algae will be added inline to water during filling of control and
test tanks at GSI. Details on these processes are available upon request and will be provided in
the final report.
Parameter
Proposed
ETV/USCG
Recommended
IMO G8
Historic Ranges*
Port of Baltimore
Historic Ranges
Duluth/Superior
Harbor
Temperature (
o
C)
10 - 35
4 - 28
9 - 22
Salinity (psu)
0 - 31
Two salinities, >10
psu difference
5 - 15
0 - 1
Total Suspended
Solids (mg/l)
> 15
> 50
1 - 60
2 - 21
Particulate Organic
Carbon (mg/l)
> 1
> 5
0.5 - 6.0
TBD
Dissolved Organic
Carbon (mg/l)
> 3
> 5
2 - 10
6 - 22
Zooplankton (> 50
µ
m) / m
3
> 10,000
> 100,000
10,000 - 300,000
10,000 - 3,000,000
Phytoplankton (10 -
50
µ
m) / ml
> 100
> 1,000
500 - 15,000
25 - 500
Heterotrophic
Bacteria cfu / ml
> 1,000
> 10,000
10,000 - 10,000,000
5,000 - 15,000