Page 14 - MERC Flip Template

Basic HTML Version

Ref. No. [UMCES] CBL 11-037
11
Hydac-5
May 25, 2011
Time Point
Total Phyto
10-50 µm (#/ml)
Total Phyto
5-10 µm (#/ml)
Ambient
Post 40 µm
Ambient
Post 40 µm
T-0 Initial
320
426
17,045
12,462
T-1
371
130
10,586
8,012
T-2
570
147
18,374
10,283
T-3
444
158
22,611
13,069
T-4
615
200
27,078
19,048
T-5
603
73
23,946
11,387
Hydac-6
May 26, 2011
Time Point
Total Phyto
10-50 µm (#/ml)
Total Phyto
5-10 µm (#/ml)
Ambient
Post 40 µm
Ambient
Post 40 µm
T-0 Initial
488
173
22,131
28,177
T-1
624
97
20,541
15,187
T-2
482
203
27,534
23,673
T-3
933
130
36,384
20,517
T-4
1,197
315
45,076
34,793
T-5
1,242
133
36,044
18,951
5.0 Acknowledgments
The MERC Testing Team included J. Barnes, T. Mullady, G. Ruiz, G. Smith, D. Sparks,
M. Tamburri, M. Wilkinson, and K. Ziombra. We wish thank the crew of the
MV
Cape
Washington
who provided critical input and support on all aspects of these trials, and the
Maryland Port Administration and U.S. Maritime Administration for funding and supporting this
ballast water treatment evaluation.