Page 53 - MERC Flip Template

Basic HTML Version

53
Table F. MERC Data Quality Objectives for Water Quality Analyses
Data Quality
Indicator
Evaluation Process
Performance Measure
MERC DQO
Precision
Analyze at least 10 % of samples
in duplicate.
Relative Percent
Difference (RPD).
< 20 % average RPD.
Accuracy
Where applicable, use a certified
reference standard to determine
differences between the measured
and nominal reference standard
concentrations.
Percent Difference (%D).
< 20 % average %D.
Representativeness Ensure pre-treatment/control and
post-treatment/treatment samples
are handled and analyzed in the
same manner.
N/A – Qualitative term.
N/A – Qualitative term.
Comparability
Routine procedures are conducted
according to appropriate SOPs to
ensure consistency between tests.
Ensure correct implementation of
SOPs.
N/A – Qualitative term.
N/A – Qualitative term.
Completeness
Calculate percentage of valid
samples analyzed out of the total
number of samples collected.
Percent Completeness
(%C)
Greater than 90 %C.