Ref. No. [UMCES]CBL 12-005
5
BOLL-5
June 2, 2011
Time point Sample ID Sample Time TSS (mg/L)
(Avg)
TSS (mg/L)
(StDev)
T0-Amb
Ambient
8:35
5.8
0.1
T0-1
Post 40 µm
8:35
5.8
0.1
T0-2
Post 40 µm
8:45
5.1
0.3
T0-3
Post 40 µm
8:55
5.4
0.2
T1-Amb
Ambient
9:50
5.8
0.6
T1-1
Post 40 µm
9:50
5.4
0.3
T1-2
Post 40 µm
10:00
5.6
0.0
T1-3
Post 40 µm
10:10
5.4
0.2
T2-Amb
Ambient
10:50
5.6
0.2
T2-1
Post 40 µm
10:50
5.3
0.2
T2-2
Post 40 µm
11:00
5.7
0.1
T2-3
Post 40 µm
11:10
5.9
0.0
4.3. Water Quality – Particulate Organic Carbon (POC)
Ambient POC samples were collected at the beginning of each major sampling period
(T0, T1, T2). Post-filter POC samples were collected for every time point (T0-1, T0-2, and T0-3,
for example). PC MDL = 0.0633 mg/L.
BOLL-1
March 16, 2011
Time point Sample ID Sample Time POC (mg/L)
(Avg)
POC(mg/L)
(StDev)
T0-Amb
Ambient
9:40
0.759
0.056
T0-1
Post 40 µm
9:40
0.733
0.011
T0-2
Post 40 µm
10:05
0.691
0.019
T0-3
Post 40 µm
10:15
0.758
0.004
T1-Amb
Ambient
12:10
1.011
0.042
T1-1
Post 40 µm
12:10
0.955
0.004
T1-2
Post 40 µm
12:23
0.961
0.018
T1-3
Post 40 µm
12:35
1.008
0.032
T2-Amb
Ambient
14:00
0.923
0.010
T2-1
Post 40 µm
14:00
0.737
0.145
T2-2
Post 40 µm
14:10
0.868
0.006
T2-3
Post 40 µm
14:20
0.880
0.001